Determines wire size to meet specific voltage drop limits or calculates voltage drop for a specific conductor run. Cable sizing software cable sizing calculation etap. From everyday cables to hardtofind specialty items, we offer a complete range of electrical, electronic, and communication copper cables that are used to transmit power, carry signal or connect devices. Choosing the right conductor size for a given application can be a daunting task. Anixter wire and cable, networking, security and utility. Differentiate and position anixter in the marketplace through communications, solutions marketing, strategic supplier relations, digital marketing or ecommerce. Home resources calculators conduit fill calculator. Typical calculations for a 20kv transformer feeder cable are presented below.
The ideal electrical design and circuit calculation software for electrical contractors, electrical consultants and electrical engineers. This wire wisdom will highlight critical considerations that influence the selection of a conductor size. With more than 65,000 products in stock, we are your trusted source for wire and cable expertise. Case study anixters cable management solution fuels. To find out how many cables you can run in a given conduit size, enter your belden cable part number, or enter the diameter of your cable. Anixter has helped the customer recognize the value of working with a supply chain solutions leader and has provided the confidence that working together on future projects of this scopeand complexitycan be accomplished. Cable sizing software that calculates optimal and cable sizes for phase conductors based on load flow, short circuit, or protective device calculation results. For eniec 609501 and eniec 623681 compliant grounding, use size 10 awg 4 mm 2 or larger copper wire and an appropriate usersupplied ring terminal. We only carry wire and cable from manufacturers you can trust. Electrical design, cable sizing and certification software. Southwires voltage drop calculator is designed for applications using awg and kcmil sizes only. Lowvoltage cable management specialists windy city wire. Southwire, an industry leader in wire and cable solutions, and go industries, dba longhorn reels, a texasbased company that manufactures wire and cable solutions, have resolved pending litigation. Etap cable sizing software provides various options which can be used for design requirements.
A marker tape under the insulation identifies the cable manufacturer, awg size and cable type. Conductor size is usually specified by american wire gauge awg, circular mil area or in square millimeters. Wire and cable is more than just copper and plastic. Windy city wire is the industry leader in cable management solutions, offering labor savings at every phase of the cable management process from concept to completion. With more than 65,000 products in stock, you have access to the largest wire and cable product offering in the world. Anixter international is a company based in glenview, illinois, united states and founded in 1957. Anixter is a leading global supplier of communications and security products, electrical and electronic wire and cable, fasteners and other small components. Determine both the 600 volt and medium voltage calculations to estimate and manage cable installation projects. Az supplies the electrical distribution and wire and chicago office headquarters az wire and cable. No signups or logins required, just click below to start sizing to either nec or iec standards.
Almost everyone has hooked up a speaker to an amplifier. Southwire recognized on top employer list for 2020. The requirements of the national electrical code nec and local codes must always be. European electricalequipment distributors rexel sa and sonepar could be attracted to anixter for its communications cable. After correct cable voltage classification the following considerations apply. Conductor size awg or kcmil 14, 12, 10, 8, 6, 4, 3, 2, 1, 10, 20, 30, 40, 250, 300, 350, 400, 450, 500, 600, 750. The recommended cable sizes are based upon information provided by the user and are intended as a guide only. Use this simple tool to calculate conduit size and fill percentage, pulling tensions, cable sidewall. In addition, although in many cases cable sizing calculations will be undertaken by the use of proprietary software, completion of the module will give the users of such packages a greater understanding of the calculations the software is undertaking, thereby enabling them to utilise such software more effectively. Product is for use in central office, catv head end, data center and. Cable sizing, sustained current capacity bs 7671 wiring regulations, voltage drop clctr 50480, fault level and impedance iec 60909. Provide financial leadership for business decisionmaking and sound, innovative planning to maximize longterm profits, cash flow and total return to shareholders. The thermocouple wire or cable is used to manufacture thermocouple probes in order to sense temperature using the point of cold junction compensation cjc end.
Etaps cable sizing analysis software can compute the size of the cables based on cable shortcircuit capacity to withstand the shortcircuit current. When sizing conductors, calculations limits wire size to voltage drop and nec ampacity. Anixter wire and cable, networking, security and utility power solutions welcome userid. Built on the science of innovation, our flagship line of copper and fiber structured cabling solutions has been meeting and beating industry standardsoftentimes before. Formula to calculate voltage drop and energy losses. The wire size calculator will give you a very simple and quick solution to the problem of calculating the size of wires and cables for pump applications in golf courses, landscape projects, and agriculture. Quick online free voltage drop calculator and energy losses calculation, formula of electrical dc and ac power wire voltage drop for various cross section cables, power factor, lenght, line, threephase, single phase. Aei accept no liability whatsoever for any use made of the proposed cable size. Conduit fill is the percent of area inside the conduit taken up by the cable s. World class is a distributor of electrical wire and cable. Then, under conduit size, select the size of your conduit and hit calculate. Our engineering services team has the latest calculation software and is able to conduct. Iec xlpe cable systems specified according to iec international electrotechnical commission are among many other standards accepted. For use as drop cable from overhead bus duct to floor machines.
Devicenet cable belden devicenet cables allow you to configure realtime networks and eliminate costly installation expenses. On the other side, as it has been explain in this other article, a thermocouple is a sensor for measuring temperature, that consists of two dissimilar metals that are joined together at the sensing end. Conductor number of insulation nominal approximate anixter size 30 awg thickness o. There does, however, remain some ambiguity over where the medium voltage cable band begins and ends, depending on the countries, the standard setting bodies, and the type of. Ul listed type rhh, ft4st1 in accordance with the national electric code. We have a fully fledged application where you can size lv and mv cables up to 33 kv, current capacity in accordance with bs 7671, era 6930 and iec 60502 and with clear easy to read calculations and reports. Cablesizer is an automated cable sizing and design calculation tool to iec and nec standards. From the everyday cables to the hardtofind specialty cables, anixter has what you need.
The short circuit current can be specified manually or obtained from the short circuit calculation. Cablesizer cable sizing calculations to iec and nec. A great tool to help electricians, engineers and contractors answer the question, what. It has a single operating site in waukesha, wi, and has about. Medium voltage cables, or mv cables, is a category defined by the international electrotechnical commission iec as having a voltage rating of above 1kv up to 100kv. Designed and manufactured for compliance with odva specifications, belden devicenet cables are approved for use within existing cable trays.
Next, select the type of conduit you are specifying. Dc ac drop voltage calculator photovoltaic software. We help our customers specify solutions and make informed purchasing. Conductor size awg or kcmil 14, 12, 10, 8, 6, 4, 3, 2, 1, 10, 20, 30, 40, 250, 300, 350. The recommendations are offered in good faith and are based upon the information supplied by the user and on the premise that one load is fed from a supply having a zero source impedance. Anixter helps its customers specify solutions and make informed purchasing decisions around technologies, applications and.
314 1533 295 1051 310 718 322 1344 366 181 1522 53 1484 1170 626 1482 1159 114 689 978 815 1270 122 1054 1231 275 749 963 1495 567 1098 618 127 1463 876 914